000 03025nam a2200253#a 4500
001 vtls000004424
008 230822s1975 xx 000 0 eng d
040 _aJPS
080 _a627.8
090 0 0 _aHYDR 627.8 KRA
100 _aKRAATZ,D B
_eauthor
245 0 _aSMALL HYDRAULIC STRUCTURES/
_cD. B. KRAATZ, I K. MAHAJAN
260 _aRome :
_bFAO,
_c1975
300 _aVarious pagin
440 _aFAO IRRIGATION AND DRAINAGE PAPER NO.26/1
505 _a2. Irrigation network operation. 2.1 General considerations. 2.2 Entirely manually operated systems 2.3 Hydro-Mechanically automated flow control. System. 2.4 Electrically-electronically automated flow control. 2.5 Manual versus automated control 2.6 Water distribution on the farm. 3. Intake structures. 3.1 Introduction 3.2 Intakes of small canals (Punjab type) 3.3 Silt selective head intake. 3.4 Constant-head orifice (CHO) intake. 3.5 Neyrpic orifice module intake. 3.6 Double orifice module intake 3.7 Open intake structures made of pre-cast reinforced concrete (U.S.S.R) 3.8 Intake structures discharging into a flume channel (U.S.S.R). 3.9 Pipe regulator with crossing into a flume channel (U.S.S.R). 3.10 Pipe regulator with crossing made of Pre-cast reinforced concrete (U.S.S.R) 3.11 Intake structure on secondary canals (Colombia). 3.12 Gate valve intake (Czechoslovakia) 3.13Venturi head intake 3.14Square-head intake. 3.15 Dupuis canal intake. 3.16 Intake with stone meshes weir (Australia) 3.17 Groyne intake and ancillary works (Cyprus) 3.18 King's silt vanes. 3.19 Gibbs Groyne. 3.20 Curved wing with silt vanes. 3.21 Reverse vanes 3.22 Vortex Tube sand trap. 3.23 Slopping. 4. Flow dividing structures. 4.1 Introduction. 4.2 Fixed proportional divisors. 4.3 Structures with adjustable splitter 4.4 Proportional distributors. 4.5 Division or diversion boxes. 5. Outlets or farm turnouts. 5.1 Introduction. 5.2 Constant- heads orifice farms turnout (U.S.A) 5.3 Neyrpic orifice module (France) 5.4 Double orifice module or siphon module. 5.5 Dethridge meter (Australia). 5.6 Plastic siphon outlets fitted with an intake tube (Turkey) 5.7 Open flume outlets (India and Pakistan)
_a5.8 Adjustable orifice semi- module (India and Pakistan) 5.9 Jamrao type orifice semi- module (Sind-Pakistan) 5.10 Pipe semi-module (India-Pakistan) 5.11 Fayoum standard weir farm outlet (Arab republic of Egypt) 5.12 Scratchily outlet(India-Pakistan) 5.13 Pipe outlets(India and Pakistan) 5.14 Farm outlet(U.S.S.R) 5.15 Pre-cast farm turnout(Turkey) 5.16 Adjustable weir farm outlets(Malaysia) 5.17 PVC pipe turnout(Republic of Korea) 5.18 Pipe outlets (Philippines) 5.19 Gated pipe outlet(Ferrara type,Italy) 5.20 Outlet structures on the farm.
546 _aIn English
650 1 0 _aHYDRAULIC
650 2 0 _aSTRUCTURES
700 _aMAHAJAN,I K.
942 _cMONO
990 _a1975
999 _a00190
_a627.8 KRA
_aVIRTUA00
_aVTLSSORT0010*0030*0050*0080*0390*0800*0900*1000*2450*2600*3000*4400*5050*5051*5460*6500*6501*7000*9040*9050*9490*9491*9492*9493*9900*9994
_c3045
_d3045
003 JPS